Checking Actual Grow Light Power with a Watt Meter

Published On: October 29, 2026
Last Updated: October 29, 2026Views: 5

In the competitive horticultural lighting market, what appears on the retail box frequently bears little resemblance to what flows through your electrical wiring. Cultivators are routinely deceived by marketing terms such as “1000W Equivalent,” “Maximum Diode Capacity 1200W,” or inflated theoretical ratings that suggest astronomical photon power. In reality, a light marketed as a “1000W LED” might draw only 185 actual watts from the wall outlet, leaving plants starving for photons and yielding airy, underdeveloped cannabis buds. Conversely, an uncalibrated, overdriven budget fixture might draw significantly more power than its circuit can safely handle, generating excessive heat and presenting a dangerous breaker-tripping hazard.

Measuring the real-world electrical consumption of your grow lights with an accurate digital watt meter is an essential baseline skill for every serious cannabis cultivator. Whether verifying that a newly purchased commercial LED luminaire meets its manufacturer specification, auditing the linearity of a 0-10V dimming controller, or calculating true Daily Light Integral (DLI) per kilowatt-hour, hands-on power measurement eliminates guesswork. Power measurements reveal driver efficiency, identify deteriorating electronic ballasts, uncover power factor penalties, and provide the hard empirical data required to calculate real operational electricity costs.

However, obtaining trustworthy electrical measurements from modern switch-mode LED drivers and high-frequency digital HID ballasts requires more than plugging in a cheap hardware-store power strip. Non-linear electronic power supplies draw distorted, non-sinusoidal current waveforms characterized by high-frequency harmonic content. Standard average-responding meters fail catastrophically when measuring these loads, introducing errors of 15 to 35 percent. Measuring real power requires understanding True RMS (Root Mean Square) sampling, distinguishing between active real power (Watts) and apparent power (Volt-Amperes), and monitoring power factor (PF).

This comprehensive technical guide provides a repeatable, laboratory-grade procedure for checking actual grow light power with a watt meter. We break down the alternating current physics governing switch-mode drivers, analyze the environmental and voltage variables that alter power draw, provide a 5-step testing protocol with calibration verification, explain how to audit dimming curves, expose common power-measurement traps, and deliver an actionable decision checklist for indoor cannabis cultivators.

Direct Answer: True Active Power vs Advertised Ratings

The single most important concept in grow room electrical auditing is that True Active Power (measured in Watts, W) is the only metric that dictates your electricity bill, the thermal heat load inside your grow tent, and the photon generation potential of your light. Advertised “equivalent wattage” numbers are purely fictitious marketing labels designed to confuse novice buyers into comparing low-cost LEDs with legacy 1000W High-Pressure Sodium (HPS) fixtures.

When conducting a physical watt meter audit on any horticultural luminaire, the cultivator should verify three core outcomes:

  • Nameplate Deviation Limit: A high-quality horticultural LED luminaire or digital ballast should draw within ±5% of its manufacturer-specified nameplate wattage when operating at nominal rated input voltage (e.g., a 650W fixture must draw between 617.5W and 682.5W). Variations exceeding ±10% indicate either fraudulent marketing specifications, an internal component defect, or severe input voltage drop.
  • High Power Factor (≥0.95): Quality commercial drivers incorporate active Power Factor Correction (PFC), maintaining a power factor between 0.95 and 0.99. A low power factor (<0.90) draws excessive apparent current (Amperes) through your branch circuits without generating additional light, heating up wiring and increasing breaker loads.
  • Dimming Linearity: When adjusting an onboard or external 0-10V dimmer, the power consumption curve should track predictably across setpoints (e.g., 50% setting on the potentiometer should draw roughly 48% to 54% of maximum full-load active wattage).
Definition

Active Real Power (Watts) vs Apparent Power (Volt-Amperes)

Active Real Power (P, Watts): The actual electrical power converted into electromagnetic light photons and dissipated thermal heat by the luminaire. This is the parameter measured by utility billing meters and watt meters. Apparent Power (S, Volt-Amperes, VA): The simple mathematical product of Root Mean Square voltage and current (V_rms × I_rms). In alternating current circuits with non-linear loads, apparent power is always equal to or greater than active power. The ratio of Real Power to Apparent Power defines the Power Factor (PF = W / VA).

Lush cannabis canopy receiving calibrated photosynthetic photon flux from tested commercial LED array
Auditing actual wall wattage with a digital watt meter ensures the canopy receives sufficient photon intensity to drive vigorous vegetative and floral development.

The Electrical Physics: True RMS, Non-Linear Loads, and Power Factor

To measure grow light electricity accurately, cultivators must understand the unique alternating current (AC) electrical behavior of modern solid-state lighting. Unlike simple resistive loads like incandescent heat lamps or space heaters, grow lights utilize switch-mode power supplies (SMPS) or high-frequency electronic ballasts that behave as non-linear electrical loads.

Linear vs Non-Linear Electrical Loads

In a purely resistive linear circuit (such as a ceramic space heater or incandescent bulb), alternating current flows in an identical smooth sine wave that is directly proportional to and in phase with the voltage waveform. Calculating power in a linear circuit is mathematically straightforward: multiplying root-mean-square voltage by current gives exact real wattage (Watts = Volts × Amps).

In contrast, modern LED drivers and digital HID ballasts are non-linear loads. They utilize full-wave bridge rectifiers and high-frequency switching transistors (operating at 50 kHz to 200 kHz) to convert AC mains power into direct current (DC) for the LED diodes. These circuits do not draw current continuously. Instead, they draw brief, violent current pulses only at the absolute peak of each AC voltage half-cycle when charging the internal DC smoothing electrolytic capacitors. This pulsed current draw distorts the electrical waveform, generating significant harmonic frequencies (3rd, 5th, 7th, and 9th harmonics) and high crest factors.

The True RMS Measurement Mandate

Because the current waveform of a grow light is severely distorted and non-sinusoidal, conventional budget multimeters fail completely. Inexpensive analog and entry-level digital meters are “average-responding” instruments. They measure the average rectified voltage or current and multiply it by 1.111 (the mathematical form factor of a perfect pure sine wave). When applied to the chopped, peaked current pulse of an LED driver, an average-responding meter can read 15% to 35% lower than the true electrical consumption.

Cultivators must utilize a True RMS (Root Mean Square) watt meter or power analyzer. True RMS instruments employ high-speed digital sampling (taking thousands of discrete voltage and current measurements per second) and compute the real effective heating value of the electrical waveform according to the fundamental mathematical formula:

$$V_{\text{RMS}} = \sqrt{\frac{1}{T} \int_{0}^{T} [v(t)]^2 dt}$$

A True RMS meter calculates instantaneous power (p(t) = v(t) × i(t)) across multiple AC cycles, capturing the true active real power regardless of waveform harmonic distortion.

Power Factor (PF) and Total Harmonic Distortion (THD)

Two crucial metrics displayed on quality watt meters reveal the electrical efficiency and grid friendliness of your grow light driver:

  • Displacement vs Distortion Power Factor: Power factor is defined as real power divided by apparent power (PF = P / S). It is comprised of two components: displacement power factor (phase shift between fundamental voltage and current) and distortion power factor (caused by harmonic currents). A power factor of 1.00 represents ideal unity power. Top-tier drivers (such as Mean Well, Inventronics, or Sosen) achieve PF > 0.95 at full load. Cheap uncertified drivers frequently exhibit PF values as low as 0.55 to 0.70.
  • Electrical Circuit Penalty of Low PF: While residential residential electric meters generally bill only for real Watts, low power factor has severe physical consequences inside your grow room. If a 600W light has a poor power factor of 0.60 on a 120V circuit, the apparent power is 1,000 VA. The luminaire draws 8.33 Amperes through your wall wires and breaker, even though it only produces 600W of light and heat. On a 15-Amp breaker (rated for 12A continuous load), you could safely run only one such fixture instead of two.
  • Total Harmonic Distortion (THD): Quantifies the total harmonic current distortion relative to the fundamental 60 Hz current. Commercial electrical standards (such as DLC V3.0 and IEEE 519) mandate THD ≤ 20% at full load. High THD creates electrical noise that can interfere with digital environmental controllers, sensors, and Wi-Fi networks.

Variables That Alter Power Consumption: Voltage, Thermal Equilibrium, and Dimming

When measuring actual grow light wattage, cultivators must account for environmental, electrical, and operational variables that cause real-world wattage to deviate from printed laboratory specifications.

1. Input Supply Voltage (120V vs 240V vs 277V)

Nearly all commercial LED grow lights utilize universal wide-input drivers capable of operating across 100V to 277V AC (or 277V to 480V for high-voltage industrial facilities). Operating the exact same luminaire on 240V rather than 120V changes its electrical characteristics:

  • Current Halving: Doubling the voltage cuts the operating current in half (Amps = Watts / Volts). A 650W light draws approximately 5.42A at 120V, but only 2.71A at 240V.
  • Driver Efficiency Gain: Switch-mode power supply transformers and MOSFET switches operate with higher thermodynamic efficiency at elevated voltages. A high-tier driver that operates at 92.5% efficiency on 120V typically achieves 94.5% to 95.0% efficiency on 240V. Consequently, the fixture draws 10 to 18 fewer gross watts from the wall to deliver the exact same optical photon output to your plants, reducing ambient heat dissipation.

Electrical Profile Across Standard Input Voltages (650W Commercial LED)

AC Supply Voltage Driver Efficiency True Active Power Operating Current Power Factor
120 Volts (Standard Residential) 92.8% 658 Watts 5.54 Amperes 0.989
208 Volts (Commercial 3-Phase Leg) 94.2% 648 Watts 3.15 Amperes 0.988
240 Volts (Residential Split-Phase) 94.8% 644 Watts 2.71 Amperes 0.986
277 Volts (Commercial Industrial) 95.2% 641 Watts 2.34 Amperes 0.982

2. Thermal Equilibrium and Cold-Start vs Hot-Run Power

Measuring a grow light the moment it is plugged into a cold room will yield inaccurate data. Cultivators must understand the semiconductor physics of light-emitting diodes:

  • Negative Temperature Coefficient of Forward Voltage: As LED diode semiconductor p-n junctions heat up, their forward operating voltage (V_f) decreases by approximately 1.5 to 2.0 millivolts per degree Celsius. In constant-current drivers, this thermal droop causes the DC electrical power delivered to the LED boards to decline slightly over the first 30 to 60 minutes of operation.
  • Thermal Stabilization Rule: When conducting a watt meter audit, a grow light must operate undisturbed at 100% output for a minimum of 45 to 60 minutes until the aluminum heat sinks reach full thermal equilibrium. Initial cold power readings are routinely 2% to 4% higher than true steady-state operating wattage.
Close inspection of trichome-laden cannabis flower under balanced spectrum grow lighting
Auditing power consumption at thermal equilibrium guarantees accurate canopy PPFD planning throughout the critical flowering phase.
Marcus Vance
via Indoor Cultivation Mechanics

Question: I bought a cheap plug-in watt meter from an online marketplace to test my new 480W LED light bar. The meter says the light is only drawing 432 Watts at 100% knob position. Did the manufacturer scam me, or is my meter wrong?

Expert Answer: Both possibilities are common, but testing order matters. First, verify whether your meter is True RMS rated. Cheap non-RMS plug-in meters under-report switch-mode power draws by 8% to 15%. Second, check your line voltage while the light is running. If your wall voltage has dropped from 120V down to 112V under load due to undersized branch wiring, constant-power drivers will adjust current, but older constant-current drivers will deliver reduced wattage. Third, test the light with a multi-turn external dimmer dial. Many budget potentiometers hit their mechanical stop before delivering the full 10V DC dimming reference signal, capping output at 90%. If your meter is a verified True RMS instrument and the wall voltage is nominal 120V, an actual draw of 432W on an advertised 480W fixture represents a 10% under-delivery, indicating an overrated retail specification.

Step-by-Step Power Measurement Protocol: Meters, Setup, and Dimming Curve Audit

Follow this rigorous 5-step engineering protocol to audit any grow light, whether a single 150W tent fixture or a multi-fixture commercial rack system.

Step 1: Select the Proper Measurement Instrument

Depending on your cultivation scale and electrical supply voltage, choose the appropriate test hardware:

  • For 120V Plug-In Fixtures (Home Tents & Small Racks): Utilize an authentic Kill A Watt P3 (Model P4400 or P4460) or a high-accuracy digital plug-in watt meter (such as the Klein Tools ET450). Ensure the meter is rated for continuous 15-Amp / 1800-Watt operation. Note that standard Kill A Watt meters are strictly rated for 120V AC and will instantly blow internal fuses if plugged into 240V circuits.
  • For 240V / 277V Hardwired or Commercial Fixtures: Utilize a calibrated True RMS AC/DC Clamp Meter (Fluke 376 FC, Klein CL800, or UEi DL389) capable of calculating active power (Watts), power factor, and crest factor. For clamp measurements, you cannot clamp around an entire outer multi-conductor jacket; you must isolate the single hot conductor (Line 1) using an AC Line Splitter (such as the Klein Tools 69409) or test directly inside an accessible junction box.
  • For Commercial Bench Testing: Utilize a dedicated benchtop digital power analyzer (Yokogawa WT310E or GW Instek GPM-8213) for laboratory-grade precision with harmonic analysis.

Step 2: Meter Baseline Calibration and Zeroing

Before connecting the grow light, verify meter zero point and supply voltage integrity:

  1. Plug the watt meter directly into the wall receptacle without any extension cords.
  2. Cycle the meter display to “Voltage (Volt RMS).” Record the open-circuit baseline voltage. A healthy North American residential receptacle should read between 118.0V and 123.0V AC.
  3. Verify the zero-watt baseline. With nothing connected to the meter receptacle, the wattage display must read strictly 0.0 W. If the meter drifts or displays ghost wattage (e.g., 1.5W with no load), power-cycle or re-zero the device.
  4. Optional Calibration Check: Plug a known pure resistive load (such as a calibrated 100W incandescent test bulb or a certified precision calibration resistor) into the meter. The meter should read within ±1% of the calibration load.

Step 3: Connect Load and Establish Thermal Equilibrium

Follow these operational conditions to record valid baseline data:

  1. Plug the grow light power cord firmly into the watt meter socket. If testing with a clamp meter, clamp around the isolated black Line conductor.
  2. Turn the fixture dimmer dial to 100% maximum output.
  3. Switch on the fixture and observe the immediate “Cold-Start Active Power” and “Cold Inrush Surge.” Record these numbers for electrical circuit headroom planning.
  4. Allow the fixture to operate continuously in ambient room temperature (70 °F to 78 °F / 21 °C to 26 °C) for 45 to 60 minutes. Do not point high-velocity oscillating fans directly at the heat sink during the test, as artificial cooling artificially suppresses thermal droop.
  5. At the 60-minute mark, observe the stable “Hot Steady-State Power (Watts).” This is the true active continuous power of your luminaire.

Step 4: Record Secondary Electrical Metrics

Cycle through the watt meter multi-function display to log the complete electrical signature:

  • Loaded AC Voltage: Observe whether line voltage has dropped under load. A drop greater than 3.0% (e.g., dropping from 121V down to 115V) indicates high resistance or excessive distance in your branch circuit wiring.
  • Operating Current (Amps RMS): Note the steady-state current draw to ensure continuous loads do not exceed 80% of circuit breaker capacity.
  • Power Factor (PF): Verify that the driver achieves PF ≥ 0.95 at 100% load.
  • Apparent Power (Volt-Amperes, VA): Confirm that VA tracks closely with Watts (VA = Watts / PF).

Step 5: Execute a Dimming Curve Linearity Audit

Many growers dim their fixtures during seedling, vegetative, and early flowering stages without knowing the actual power delivered. Execute a 5-point dimming calibration test:

Dimmer Knob Setting Target Ideal Power (650W Base) Expected Tolerable Range Typical Low-End Anomaly
100% (Maximum / Off-Detent) 650 Watts 620W – 670W Full rated output achieved.
75% (Late Vegetative / Transition) 488 Watts 460W – 510W Generally linear response.
50% (Early Vegetative / Mothers) 325 Watts 300W – 350W Potentiometer tolerance drift (±10%).
25% (Rooted Clones / Seedlings) 163 Watts 140W – 190W Power factor drops significantly (PF ~ 0.85).
10% (Minimum Dimming Floor) 65 Watts 55W – 85W Driver “dim-to-off” threshold or flickering floor.

Log these actual wattages on a physical index card taped to your grow tent frame. This allows you to dial in precise Photosynthetic Photon Flux Density (PPFD) levels without guessing potentiometer percentages.

Common Measurement Mistakes, Inaccurate Tools, and Deceptive Claims

Avoid these widespread errors that lead cultivators to draw incorrect conclusions regarding their lighting performance.

1. Testing Through Long, Undersized Extension Cords

Placing a watt meter at the end of a 50-foot 16 AWG extension cord introduces significant series resistance. Under a 600W load, the resistance of the thin extension cord causes a severe voltage drop (often 4 to 8 volts). When supply voltage drops, some constant-power LED drivers draw increased current to compensate, while budget drivers throttle output, skewing measurement results. Always plug your watt meter directly into the branch wall receptacle.

2. Conflating Idle Standby Power with Off-State Power

When modern LED fixtures with digital 0-10V controllers or RJ45 daisy-chain cables are dimmed to “OFF” via a central lighting controller, the luminaire diodes stop emitting light. However, the internal driver auxiliary power supply remains energized to power the internal microprocessor and communication circuitry. A watt meter audit will reveal that a “dimmed off” 650W light still draws 3 to 12 Watts of continuous phantom standby power. Across a 20-light commercial room, phantom power draws 120W to 240W around the clock. To achieve true zero power consumption during the dark cycle, the AC mains branch must be physically disconnected via a mechanical contactor relay or digital timer.

3. Confusing Total Diode Theoretical Capacity with Wall Draw

A common fraudulent marketing tactic among budget online sellers is advertising “diode math.” For example, a fixture equipped with 400 pieces of 3-watt SMD LEDs is aggressively marketed as a “1200W Grow Light.” When connected to a watt meter, the actual wall draw is revealed to be a mere 220 Watts. The seller defends this by arguing that 400 × 3W = 1200W theoretical maximum capability. In solid-state horticultural lighting, LEDs are deliberately underdriven at 20% to 40% of their maximum rated current to maximize photosynthetic efficacy (μmol/J) and prevent thermal failure. Real wall power is the only valid metric for grow planning.

What to Do

  • Use a True RMS rated digital watt meter or power clamp meter.
  • Allow fixtures to operate for 45-60 minutes to reach thermal equilibrium before recording final data.
  • Log loaded supply voltage alongside active power to evaluate branch circuit health.
  • Audit power consumption across the full dimming range to calibrate true canopy intensity.
  • Check Power Factor (PF ≥ 0.95) to ensure breaker continuous capacity is not overloaded.

What to Avoid

  • Do not rely on cheap average-responding multimeters that miscalculate non-linear pulsed currents.
  • Do not plug standard 120V Kill A Watt meters into 240V commercial electrical circuits.
  • Avoid measuring power through long, lightweight 16 AWG extension cords.
  • Do not trust retail “equivalent wattage” claims or theoretical maximum diode capacity math.
  • Avoid assuming 0-10V dimmers are perfectly linear across budget potentiometers.

How to Verify Driver Health, Ballast Losses, and Photosynthetic Efficacy

Beyond merely validating manufacturer marketing specs, routine watt meter auditing serves as an invaluable diagnostic tool throughout the lifecycle of your indoor cultivation facility.

Auditing Electronic Ballast Losses in Legacy HPS/CMH Fixtures

Growers operating Ceramic Metal Halide (CMH) or High-Pressure Sodium (HPS) systems must understand that the lamp wattage does not represent the total electrical draw. Electronic and magnetic ballasts consume significant internal energy to generate striking voltages and regulate arc currents:

  • High-Frequency Digital Ballasts: A standard 1000W DE (Double-Ended) HPS digital ballast typically draws 1,055 to 1,080 actual wall watts at full output (representing 55W to 80W of internal ballast dissipation loss).
  • Magnetic Core-and-Coil Ballasts: Older magnetic ballasts are notoriously inefficient, drawing 1,120 to 1,180 actual watts to drive a 1000W bulb, with power factors frequently dropping to 0.85 without power factor correction capacitors.

If a watt meter reveals an HPS ballast drawing over 1,150W or exhibiting a power factor below 0.90, the ballast capacitor is degrading, generating excessive waste heat and risking imminent failure.

Calculating True System Photosynthetic Photon Efficacy (PPE)

When paired with a calibrated quantum PAR meter or integrated sphere laboratory data, measuring true wall wattage allows cultivators to calculate real-world Photosynthetic Photon Efficacy (PPE):

$$\text{PPE } (\mu\text{mol/J}) = \frac{\text{Total Photon Output } (\mu\text{mol/s})}{\text{True Active Wall Power } (\text{Watts})}$$

If a manufacturer claims their fixture produces 1,750 μmol/s of photosynthetic photon flux (PPF) from an advertised “600W” fixture, but your watt meter reveals the actual wall consumption is 680W, the real system efficacy is 2.57 μmol/J, not the 2.92 μmol/J claimed on the box. Verifying real wall power protects cultivators from inflated efficacy claims and guarantees realistic crop yield expectations.

Weedth Experience

The Mystery of the Tripping 20-Amp Flower Room Breaker

In a commercial micro-facility in Michigan, a grower installed three new commercial LED fixtures rated at 680W each on a single dedicated 20-Amp, 120V branch circuit. The grower calculated that 3 × 680W = 2,040 Watts. Under the 80% continuous breaker rule (1,920W maximum on a 20A circuit), he knew he was slightly over the limit, but assumed the manufacturer-stated 650W nominal draw would hold. Within two hours of photoperiod start, the circuit breaker repeatedly tripped. When we plugged a True RMS power analyzer into the fixtures, we discovered two critical problems: First, the fixtures actually drew 715 Watts each at thermal equilibrium (2,145W total active load). Second, the uncertified budget drivers exhibited a poor power factor of 0.86, resulting in an apparent power draw of 2,494 VA and an operating current of 21.3 Amperes. The branch circuit was operating at 106% of breaker trip capacity. Moving the fixtures to a 240V supply immediately halved the current draw to 10.6A, resolving the breaker trips and lowering driver operating temperatures by 8 °C.

High-density trichomes on mature cannabis calyx reflecting optimized light spectrum
Precise power auditing ensures LED arrays operate at peak thermodynamic efficiency, maximizing cannabinoid synthesis and terpene preservation.

Watt Meter Testing Checklist and Next Weedth Resources

Execute this practical checklist whenever commissioning new grow lights or conducting an annual electrical health audit of your cultivation facility.

Grow Light Power Measurement Protocol Checklist
✓ True RMS Meter Verified: Confirmed the test meter is True RMS rated to accurately capture non-linear switch-mode harmonics.
✓ Direct Receptacle Connection: Meter plugged directly into the wall outlet with zero lightweight extension cords in the measurement path.
✓ Unloaded Voltage Baseline: Recorded open-circuit line voltage (target: 118V – 123V for 120V circuits; 236V – 244V for 240V circuits).
✓ Thermal Equilibrium Reached: Fixture operated at 100% full load for a full 45 to 60 minutes before logging final steady-state wattage.
✓ Nameplate Deviation Calculated: Verified steady-state active wattage is within ±5% of manufacturer printed specification.
✓ Power Factor Audited: Verified Power Factor is ≥0.95 at 100% output to avoid excessive branch circuit current loading.
✓ Voltage Drop Under Load Checked: Confirmed loaded voltage drop does not exceed 3.0% from unloaded baseline.
✓ Dimming Linearity Calibrated: Tested power draw at 25%, 50%, 75%, and 100% settings and documented actual wattages for canopy PPFD management.
✓ Standby Phantom Power Noted: Measured phantom wattage when dimmed to OFF to decide whether mechanical relays are necessary.
✓ Circuit Headroom Re-evaluated: Summed total measured Amperes to verify continuous circuit breaker loading remains strictly ≤80%.

Scientific References

  1. Illuminating Engineering Society (IES). (2019). ANSI/IES LM-79-19: Optical and Electrical Measurements of Solid-State Lighting Products. Illuminating Engineering Society, New York, NY.
  2. Institute of Electrical and Electronics Engineers (IEEE). (2010). IEEE Std 1459-2010: Standard Definitions for the Measurement of Electric Power Quantities Under Sinusoidal, Nonsinusoidal, Balanced, or Unbalanced Conditions. IEEE, Piscataway, NJ.
  3. International Electrotechnical Commission (IEC). (2018). IEC 61000-3-2: Electromagnetic compatibility (EMC) – Part 3-2: Limits – Limits for harmonic current emissions. IEC, Geneva, Switzerland.
  4. National Electrical Manufacturers Association (NEMA). (2017). NEMA SSL 1-2017: Electronic Drivers for LED Devices, Arrays, or Systems. NEMA, Rosslyn, VA.
  5. Radetsky, L. C. (2018). Evaluating the Performance of LED Grow Lights for Controlled Environment Agriculture. Lighting Research Center, Rensselaer Polytechnic Institute, Troy, NY.
  6. Nelson, J. A., & Bugbee, B. (2014). Economic analysis of greenhouse lighting: light emitting diodes vs. high intensity discharge fixtures. PLOS ONE, 9(6), e99012. DOI: 10.1371/journal.pone.0099012