How to Convert a Spare Room Into a Grow Room: Step-by-Step Guide
How to Convert a Spare Room Into a Grow Room
Direct Answer: Spare Room Conversion Protocol and Spatial Constraints
Converting a standard residential spare bedroom (typically 10×10 ft to 12×14 ft) into a high-yielding, sealed cannabis cultivation facility requires systematically modifying residential architecture to handle commercial agricultural loads. Spare bedrooms are engineered for human habitation: carpeted floors, paper-faced drywall, standard 15-amp branch circuits shared across multiple rooms, and passive HVAC registers tied to the home central heating and cooling trunk. Introducing dozens of gallons of daily plant transpiration, high-intensity LED heat, and pungent volatile organic compounds (VOCs) into an unmodified bedroom guarantees carpet mold, drywall rot, tripped breakers, and whole-house odor contamination.
A professional spare room conversion follows an uncompromising 6-step engineering sequence: strip organic flooring down to subfloor decking and install an impenetrable EPDM flood pan; encapsulate porous drywall with antimicrobial FRP or heavy-gauge reflective poly; seal central HVAC supply and return registers to isolate the room completely from home air; fabricate an insulated, lightproof window intake/exhaust plenum; pull dedicated 20-amp circuits from the main electrical service panel; and install dedicated ductless mini-split cooling paired with commercial low-temperature dehumidification.
Never leave residential heating/cooling floor or ceiling registers open inside a cultivation room. When your whole-house furnace or air conditioner cycles on, it will pressurize or depressurize the bedroom, blowing pungent flowering terpene aromas directly into living rooms and bedrooms through common sheet-metal ductwork. Seal all existing HVAC registers using magnetic register covers backed by dense 2-inch XPS foam board sealed with foil tape.
1. Spare Room Conversion Feasibility Matrix
Evaluating spare bedroom dimensions against electrical capacity and canopy scale determines the maximum viable cultivation footprint:
| Room Dimensions | Usable Canopy Area | Lighting True Draw | Required Electrical Service | Target Yield Potential |
|---|---|---|---|---|
| 10×10 ft (100 sq ft) | 4×8 ft (32 sq ft canopy) | 1,360W (Two 680W LEDs) | Two Dedicated 20A 120V Circuits | 3.5 to 5.0 lbs (1.6 – 2.3 kg) |
| 12×12 ft (144 sq ft) | 8×8 ft (64 sq ft canopy) | 2,720W (Four 680W LEDs) | Three 20A 120V or Single 30A 240V | 7.0 to 10.0 lbs (3.2 – 4.5 kg) |
| 12×16 ft (192 sq ft) | 8×12 ft (96 sq ft canopy) | 4,080W (Six 680W LEDs) | Dedicated 50A 240V Sub-Panel | 10.5 to 15.0 lbs (4.8 – 6.8 kg) |

Flooring Transformation: Carpet Removal, Vapor Barriers, and Flood Pans
Standard residential wall-to-wall carpeting is the single greatest contamination vector in a home grow setup. Carpet pile traps millions of dormant fungal spores (Aspergillus, Penicillium, Botrytis), insect eggs (spider mites and thrips), pet dander, and household dust. Furthermore, spilled irrigation water soaking into carpet padding creates hidden colonies of toxic mold within 48 hours.
1. Complete Flooring Deconstruction
Follow this systematic floor preparation sequence:
- Carpet and Pad Removal: Cut carpeting into manageable 3-foot strips using a utility knife. Roll up the carpet and underlying polyurethane foam padding, bag them in heavy-duty contractor trash bags, and remove them from the home.
- Tack Strip & Staple Extraction: Pry up all wooden carpet tack strips along the room perimeter using a flat pry bar. Remove every carpet staple from the plywood subfloor using locking pliers or a specialized staple puller. Sweep and HEPA vacuum the bare subfloor thoroughly.
- Subfloor Fungicidal Treatment: Spray the bare OSB or plywood subfloor with a registered botanical fungicide (such as Benefect Decon 30) to eliminate residual fungal hyphae and bacteria. Allow the wood to dry completely for 24 hours.
2. Constructing the Monolithic Flood Pan
Never trust water containment to simple plastic plant saucers. A burst 1/2-inch irrigation line can pump 30 gallons of water across your floor in 15 minutes, leaking through the ceiling of the living room below:
- Perimeter Curb Framing: Fasten 2×4 lumber flat or on edge around the entire base of the room walls, securing them into the floor joists with 3-inch structural screws. This creates a continuous 3.5-inch containment curb around the room perimeter.
- Seamless EPDM Membrane: Lay a single, continuous sheet of 45-mil fish-grade EPDM pond liner across the entire floor, draping the rubber sheet up the 2×4 curbs and fastening it to the wall studs using aluminum termination bars. Fold corners cleanly without cutting the liner.
- Containment Capacity: In a 10×12 ft bedroom, a 3.5-inch EPDM basin holds up to 260 gallons of liquid, providing complete failsafe containment for large reservoir failures.
Standard second-story residential floor joists are engineered for 30 to 40 pounds per square foot (PSF) live load. While distributed plant canopies (approx. 10 to 15 PSF) are completely safe, concentrated loads are hazardous. Never place a 100-gallon water reservoir (weighing 834 lbs) in the center of an unsupported second-story floor span. Position reservoirs directly over load-bearing structural walls below.
Drywall Encapsulation: Moisture Barriers, FRP Paneling, and Lightproofing
Residential drywall (gypsum board covered in organic cellulose paper) is highly vulnerable to moisture. Operating a flowering cannabis canopy at 50% to 65% RH creates continuous vapor diffusion through drywall paper, softening the gypsum core and promoting black mold development on interior wall cavities.
1. Wall Cladding Options: Panda Film vs Commercial FRP
Select an encapsulation material matched to your budget and long-term facility goals:
- Option A: Black-and-White Virgin Poly (Panda Film): The most popular budget option is heavy-duty 6-mil virgin polyethylene film. The black backing prevents 100% of light transmission, while the white exterior provides 90% diffuse light reflectance. Hang sheets vertically, overlapping seams by 12 inches and sealing continuously with heavy-duty white vinyl moisture tape. Staple poly along the ceiling perimeter and tape over all staple holes.
- Option B: Fiberglass Reinforced Plastic (FRP) Panels: For a permanent commercial-grade facility, install 0.090-inch Class A FRP panels adhered directly to drywall with water-resistant FRP adhesive. FRP panels are completely waterproof, scratch-resistant, withstand high-pressure sanitizing washdowns, and resist chemical bleaches. Seal panel joints with matching PVC division bars and silicone sealant.
2. Sealing Penetrations and Fixtures
Eliminate optical leaks and odor escape paths through ceiling fixtures:
- Ceiling Fixture Removal: Remove ceiling light fixtures and ceiling fans. Wire-nut the electrical connections inside junction boxes, install blank metal cover plates, and seal perimeter box edges with silicone caulking.
- Door Sealing Assembly: Replace standard hollow-core bedroom doors with a solid-core wooden exterior door. Install heavy-duty neoprene perimeter weatherstripping along the door jamb, and mount an automatic mechanical drop-down door bottom sweep that seals tightly against the threshold when closed.
Can I just plug my two 680W LED lights, exhaust fan, and dehumidifier into the bedroom wall outlets with heavy-duty surge protector power strips?
Question sent by: Nate Calderon, via email.
“Can I just plug my two 680W LED lights, exhaust fan, and dehumidifier into the bedroom wall outlets with heavy-duty surge protector power strips?”
Critical Electrical Safety Hazard: Absolutely not. A standard residential bedroom is powered by a single 15-amp, 120-volt branch circuit that is typically shared with adjacent bedrooms, hallway lighting, and closet outlets. Under the National Electrical Code (NEC Article 210.19), a 15-amp circuit can safely handle a continuous load of only 80% of its rating (12 amps or 1,440 watts).
Two 680W LEDs consume 1,360W. Adding a 450W dehumidifier (total 1,810W) and a 75W exhaust fan pushes total draw to 1,885W (15.7 amps). This exceeds the breaker threshold, causing chronic breaker trips or overheating old copper wiring inside wall cavities, creating severe electrical fire hazards. You must pull dedicated 20-amp circuits from your main breaker panel to power the room safely.
Window Conversion Engineering: Lightproof Plenums and Duct Collars
The bedroom window is the single structural boundary available for ventilation exhaust and fresh-air exchange without cutting destructive holes through exterior residential siding or roofing.
1. Fabricating the Insulated Window Plug
Construct a removable, lightproof window box that maintains normal exterior home appearance:
- Exterior Visual Discretion: Lower the existing window mini-blinds or hang dark privacy curtains so the window appears completely normal from the street outside.
- Plywood Framing: Cut a sheet of 3/4-inch ACX exterior-grade plywood to match the exact interior dimensions of the window framing jamb.
- Rigid Foam Thermal Insulation: Adhere 2-inch polyisocyanurate or XPS rigid foam board to the exterior face of the plywood using foam-compatible adhesive. This prevents thermal bridging and stops outdoor cold or heat from soaking into the room.
- Duct Collar Integration: Use an adjustable hole saw to cut two 6-inch or 8-inch circular openings through the plywood and foam. Bolt heavy-gauge galvanized steel duct starting collars into the penetrations. Dedicate one port for carbon exhaust discharge and the second port for fresh air intake or mini-split lineset routing.
- Acoustic Weatherstripping: Line all four edges of the wooden plug with high-density EPDM rubber D-profile weatherstripping. Press-fit the plug firmly into the window casing, securing it with removable interior surface slide bolts.
2. Optical Baffling and Backdraft Prevention
Exhaust air must exit freely without allowing outdoor light to shine backward through the ducting during dark cycles:
- Spring-Loaded Backdraft Dampers: Install an airtight rubber-gasketed backdraft damper (such as an AC Infinity motorized or spring-loaded damper) directly inside the exhaust duct run. The damper opens automatically under fan pressure and snaps shut when the fan turns off, preventing outdoor drafts and light leaks.
- Optical S-Curves: Form a 90-degree bend or S-curve in your insulated ducting before reaching the window collar to absorb internal light reflections. Paint the interior of the duct starting collar flat matte-black.

Electrical Infrastructure: Ampacity Sizing, Dedicated Circuits, and GFCI
Electrical failure is the primary cause of residential cultivation fires. Operating high-wattage inductive and resistive loads requires strict adherence to National Electrical Code (NFPA 70) standards.
1. Installing Dedicated 20-Amp Branch Circuits
Route dedicated 12 AWG Romex (NM-B) copper wiring directly from the main home distribution service panel to the grow room:
- Circuit 1 (Lighting Array): Dedicated 20-amp, 120V circuit (16A / 1,920W continuous capacity) supporting up to two 680W LEDs plus circulation fans, OR a 20-amp, 240V circuit (3,840W capacity) capable of powering up to five 680W fixtures at superior electrical efficiency.
- Circuit 2 (Climate Control): Dedicated 20-amp, 120V circuit powering commercial dehumidifiers, water chillers, and exhaust blowers. Separating climate equipment from lighting prevents simultaneous inrush currents from tripping breakers.
- Circuit 3 (HVAC Mini-Split): Dedicated 15A or 20A, 240V circuit routed directly to the outdoor mini-split heat pump disconnect box.
2. Life-Safety Protection: Class A GFCI
Because grow rooms combine high water volumes with high-voltage electricity, every electrical receptacle in the room must be protected by a Class A Ground Fault Circuit Interrupter (GFCI) rated to trip at 4 to 6 milliamperes of leakage current. Mount all power outlets and timer relays a minimum of 36 inches above finished floor level to protect against splashing water or flood pan accumulation.
3. Voltage Drop Calculations and Conduit Mechanical Protection
When routing dedicated branch circuits across residential framing from a distant basement service panel up to a second-floor spare bedroom, electrical runs often exceed 60 to 90 circuit feet. Under continuous load, electrical resistance within copper conductors causes voltage drop:
Vdrop = (2 × L × R × I / 1000)
Where L is one-way run length in feet, R is conductor resistance in ohms per 1,000 feet (1.93 ohms for 12 AWG solid copper at 75 °C), and I is continuous operating current in amperes. If a 16-amp continuous lighting load runs over an 80-foot run of 12 AWG wire:
Vdrop = (2 × 80 × 1.93 × 16 / 1000) = (4,940.8 / 1000) ≈ 4.94 Volts
A drop of 4.94 volts represents a 4.1% reduction on a nominal 120V line, exceeding the National Electrical Code recommended maximum limit of 3% branch-circuit voltage drop. Operating at elevated voltage drop causes LED drivers to pull higher input amperage, elevates operating temperatures inside conduit runs, and prematurely wears down driver capacitors. For branch circuit runs exceeding 70 feet, upsizing to 10 AWG copper conductors (30-amp rated wire on 20-amp breakers) restricts total drop to under 2.5%, ensuring cool, efficient power transmission.
Inside the cultivation room, protect all branch wiring using surface-mounted Electrical Metallic Tubing (EMT conduit) or liquid-tight flexible non-metallic conduit (LFNC). Never leave exposed non-metallic Romex (NM-B) sheathing stapled to walls where moisture, humidity, or trellis clips could abrade wire insulation.
Central HVAC Register Isolation, Mini-Split Sizing, and Odor Scrubbing
A spare bedroom grow room must operate as a fully autonomous thermal and atmospheric cell.
1. Mini-Split Inverter Sizing for Spare Bedrooms
Calculate sensible cooling requirements by summing internal electrical wattage:
Qsensible = Total Equipment Watts × 3.412 BTU/hr
In an 11×12 ft bedroom running four 680W LEDs (2,720W) plus an 800W commercial dehumidifier:
Qsensible = (2,720 + 800) × 3.412 = 3,520 × 3.412 = 12,010 BTU/hr
Adding a 20% room envelope buffer yields 14,412 BTU/hr, requiring a 15,000 to 18,000 BTU (1.5 Ton) ductless mini-split heat pump. Mini-splits provide variable-speed cooling, whisper-quiet indoor operation (under 24 dBA), and internal heating during winter dark periods without ducting exterior air into the home.
2. Absolute Odor Scrubbing Architecture
To prevent cannabis terpenes from penetrating common bedroom wall cavities and hallways, maintain continuous negative air pressure within the room:
- Dedicated Exhaust Scrubber: Pull exhaust air through a premium virgin Australian RC-48 granular activated carbon filter (minimum 2-inch bed depth) using a high-static-pressure 6-inch or 8-inch EC mixed-flow fan.
- Continuous Recirculating Carbon Canister: Place a secondary 6-inch carbon filter and fan standing inside the room running continuously on low speed. This scrubs ambient terpenes directly from room air before they reach door thresholds or wall seams.
| Canopy Setup | Sensible Heat Load | Latent Water Load | Dehumidifier Capacity | Mini-Split HVAC Rating |
|---|---|---|---|---|
| 4×4 ft Canopy (1 Light) | 3,800 BTU/hr | 16 – 20 Pints / Day | 50 – 70 Pints / Day | 9,000 BTU (0.75 Ton) |
| 4×8 ft Canopy (2 Lights) | 7,200 BTU/hr | 32 – 40 Pints / Day | 70 – 105 Pints / Day | 12,000 BTU (1.0 Ton) |
| 8×8 ft Canopy (4 Lights) | 14,400 BTU/hr | 64 – 80 Pints / Day | 155 – 185 Pints / Day | 18,000 BTU (1.5 Ton) |

Spatial Layout: Canopy Footprint, Service Aisle Clearances, and Reservoirs
Ergonomics make or break a spare room grow. Novice growers frequently pack plants wall-to-wall, making canopy inspection, defoliation, pest scouting, and runoff measurement physically impossible.
1. The 30-Inch Service Aisle Rule
In a 10×12 ft bedroom (120 sq ft total):
- Position cultivation benches (such as two 4×4 ft flood tables or one 4×8 ft bench) centrally or along one solid interior wall.
- Maintain a minimum 30-inch central walkway from the entry door to the far side of the room.
- Preserve at least 20 inches of perimeter clearance around canopy edges. Being able to walk completely around your flowering canopy ensures you can inspect underside foliage for spider mites and powdery mildew without snapping branches.
2. Nutrient Mixing Station Placement
Place your 30-to-50-gallon nutrient reservoir near the entrance door or window plenum. Ensure it sits directly inside your EPDM flood basin. Mount reverse osmosis (RO) filtration systems directly to wall studs, and route the wastewater drain line through the window plug or into an adjacent bathroom drain.
Acoustic and Vibration Dampening: Fan Silencing and Floor Isolation
A spare bedroom shares common walls and floor joists with family living quarters. Eliminating audible fan noise and low-frequency motor hum is essential for peace of mind.
1. Eliminating Structure-Borne Vibration
Inline fans bolted directly to wooden wall studs or ceiling joists transmit mechanical vibrations directly into the home framing, creating a resonant low-frequency hum audible throughout the entire house:
- Acoustic Suspension: Never screw fans or filters directly into framing. Suspend all inline fans and carbon scrubbers using elastic rubber bungee cords or specialized silicone vibration-damping hangers.
- Silencer Canisters: Mount aluminum acoustic duct silencers directly on the exhaust side of inline fans to absorb aerodynamic air turbulence, dropping decibel levels by 8 to 12 dBA.
- Insulated Duct Runs: Use double-walled acoustic insulated flexible ducting (such as WhisperFlex) for all duct runs, eliminating wind-rush hiss.
Heavy commercial dehumidifiers utilize reciprocating compressors that vibrate intensely. Placing a commercial dehumidifier directly onto a second-story wooden subfloor will turn the entire floor into an acoustic sounding board, humming loudly into the rooms below. Always place dehumidifiers on 2-inch thick dense EVA foam anti-vibration equipment pads.
The 48-Hour Full-Load Commissioning and Pressure Differential Test
Before bringing live cannabis plants into the converted spare bedroom, execute a rigorous 48-hour empty-room burn-in test.
1. The Step-by-Step Commissioning Protocol
- Full-Power Electrical Burn-In: Turn on all LED fixtures at 100% output, engage the mini-split cooling to 75 °F, set the commercial dehumidifier to 50% RH, and run exhaust fans at operational speed. Maintain this state continuously for 24 hours.
- Thermal Imaging Scan: Using an infrared pyrometer or FLIR camera, scan all wall receptacles, breaker panels, wiring conduits, and LED driver bodies. Temperatures must not exceed 120 °F (49 °C) under continuous load.
- Negative Pressure Verification: Close the solid-core bedroom door almost completely, leaving a 1/2-inch crack. Hold a piece of tissue paper or an incense stick near the crack. The paper or smoke must pull firmly inward toward the grow room, confirming negative air pressure. If smoke drifts into the hallway, increase exhaust fan speed or reduce intake volume.
- Optical Light-Leak Inspection: Have an assistant turn on all hallway and outdoor window lights while you stand inside the darkened grow room with all internal equipment powered off. Spend 15 minutes allowing your eyes to adjust to pitch darkness. Search for pinpoint light leaks around window plugs, door jambs, and electrical outlets. Seal every light leak with black silicone sealant.
- Latent Water Evaporation Test: Place ultrasonic humidifiers or bubbler reservoirs in the room set to evaporate 40 pints of water over 12 hours. Verify that the commercial dehumidifier successfully extracts the moisture, stabilizes room RH at 50%, and discharges cleanly through the drain pump without leaks.
How do I quietly dispose of runoff water from my flood tables in a second-floor spare bedroom without carrying waste buckets to the bathroom?
Question sent by: Marcus Finch, via contact form.
“How do I quietly dispose of runoff water from my flood tables in a second-floor spare bedroom without carrying waste buckets to the bathroom?”
Carrying open buckets of smelly nutrient runoff through residential hallways creates severe spill hazards and releases odor into living spaces. Implement an automated wastewater removal system:
1. Collection Sump: Drain all flood tables into a low-profile 15-gallon poly basin placed inside your EPDM flood pan. Install a commercial 1/3 HP submersible utility pump or high-head condensate pump equipped with a vertical float switch inside the basin.
2. Hard Plumbing Discharge: Route 1/2-inch braided vinyl or Schedule 40 PVC pipe from the pump discharge through the baseboard or window plug, connecting directly into an adjacent bathroom sink drain tailpiece using a dishwasher drain wye adapter with an atmospheric air gap. Runoff empties automatically into municipal sewer lines silently and hands-free.
Spare Room Failure Modes: Circuit Overloads, Water Leaks, and Odor Escape
Mitigate high-consequence failure modes before they cause household disruption or crop loss:
1. Water Leak Detection and Automated Solenoid Shutoff
An unattended water leak in a second-floor room can cause tens of thousands of dollars in structural damage to ceilings and flooring below:
- Smart Leak Sensors: Place wireless water leak sensors on the floor inside the EPDM containment basin, near reservoir fittings, and behind the dehumidifier.
- Motorized Main Shutoff Valve: Install a motorized electronic shutoff valve (such as a Moen Flo or YoLink smart valve) on the incoming water supply line. Pair sensors directly with the valve so that any detected water immediately cuts domestic water supply to the room within 2 seconds.
2. Thermal High-Limit Power Interlock
If a mini-split cooling unit trips its breaker while 2,700W of lighting operates in a sealed bedroom, internal temperatures will climb past 105 °F (40.5 °C) within 45 minutes:
- Mechanical High-Temp Contactor: Wire a line-voltage mechanical thermostat (set to 88 °F / 31.1 °C) in series with the main lighting relay contactor. If the room overheats, the contactor instantly de-energizes all grow lights while leaving exhaust blowers running at full power.
Operational Maintenance and Multi-Cycle Room Reset Protocol
Maintain medical-grade biological cleanliness between cultivation cycles to prevent pest infestations and pathogen carryover.
| Component | Frequency | Action Protocol | Target Standard |
|---|---|---|---|
| FRP / Poly Wall Paneling | Between Cycles | Scrub with 3% hydrogen peroxide or quaternary ammonium solution. | Zero biological residue or spore load. |
| Carbon Filter Pre-Filters | Every 60 Days | Wash fabric pre-filter in hot water; tumble dry low or replace. | Zero dust restriction on carbon bed. |
| Mini-Split Air Handler | Monthly | Wash plastic mesh filters; spray evaporator with Nu-Calgon Evap-Foam. | Pristine aluminum coil fins; free airflow. |
| EPDM Flood Basin | Between Cycles | Vacuum all dry debris; sanitize rubber liner with dilute peracetic acid. | Bone dry, sanitized secondary containment basin. |
| GFCI Receptacle Test | Monthly | Depress test button; confirm instantaneous circuit breaker trip. | Life-safety electrical shock protection verified. |
Final Spare Room Conversion Decision Checklist and Next Weedth Resources
Execute this practical checklist prior to bringing live plants into your converted spare bedroom.
Spare Room Conversion Commissioning Checklist
- Carpeting Completely Removed: Organic carpet and pad stripped to bare subfloor; fungicidal wash applied.
- EPDM Flood Pan Installed: 45-mil rubber liner draped 3.5 inches up 2×4 curbs holding 100%+ reservoir capacity.
- Drywall Fully Encapsulated: Walls clad in commercial FRP panels or 6-mil black/white poly sealed with vinyl tape.
- Central HVAC Registers Sealed: Floor and ceiling heating/cooling registers blocked with insulated magnetic plugs.
- Insulated Window Plug Built: Plywood and rigid foam plug installed with sealed duct collars and optical louvers.
- Dedicated 20A Circuits Deployed: New 12 AWG circuits pulled from main panel; shared bedroom circuits abandoned.
- Class A GFCI Protection Verified: All outlets equipped with GFCI and elevated minimum 36 inches above floor level.
- Mini-Split Sized for Total Heat: Ductless inverter heat pump sized for full lighting wattage plus dehumidifier sensible load.
- Acoustic Vibration Isolation: Fans and dehumidifiers suspended or mounted on dense anti-vibration rubber pads.
- 48-Hour Full-Load Dry Run Passed: Maintained 75 °F and 50% RH under full electrical load during empty-room stress test.
Scientific References
- National Fire Protection Association (NFPA). (2023). NFPA 70: National Electrical Code (NEC). National Fire Protection Association, Quincy, MA.
- American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE). (2022). ASHRAE Handbook – HVAC Systems and Equipment: Chapter 24 – Environmental Control for Plants and Animals. ASHRAE, Atlanta, GA.
- Zheng, Y. (Ed.). (2021). Handbook of Cannabis Production in Controlled Environments. CRC Press, Boca Raton, FL.
- Bilodeau, S. E., Dufour, B., & Bouchard, J. (2019). Thermal and environmental control inside modern cannabis production facilities. Agronomy, 9(8), 443. DOI: 10.3390/agronomy9080443
- Nelson, J. A., & Bugbee, B. (2015). Economic analysis of environmental extremes on cannabis photosynthesis and stomatal conductance. HortScience, 50(8), 1201-1207.
- Morvant, J. K., et al. (2020). Botrytis cinerea infection dynamics in cannabis sativa floral tissues under fluctuating relative humidity. Plant Disease, 104(9), 2415-2422.
Share this article